Neax 2000 Ips Matworx Download
Hey Guys I just got a scrapped NEAX 2000 IPS from a company and was just working on it to see how it functions. I;m new to PBX and wanted. You will need a terminal emulator to talk to the system, Hyperterminal will do but if that isn't available, download a free one like Terraterm. Even better (if you can.
NEC NEAX IPX DM NEC NEAX IPX DM 08 January 2004 Richard A. Costello Document Type: Product Report Note Number: DPRO-112322 This distributed model targets midsize and large-size enterprises looking to deploy IP peer-to-peer voice switching.
Its system footprint (only a 19-in. Rack module) is significantly smaller than traditional PBX systems. Table of Contents • • • • • • • • List of Tables • Table 1: • Table 2: • Table 3: • Table 4: • Table 5: Corporate Headquarters NEC America, Inc. Corporate Networks Group (CNG) 6555 N.
State Highway 161 Irving, TX, U.S.A. Tel: +1 214 262 2000 Internet: Table 1 NEAX Internet Protocol eXchange Distributed Model (NEAX IPX DM) Product Name NEAX IPX DM Product Type Digital private branch exchange (PBX) Federal Communications Commission (FCC) Registration Number AY5USA-74913-MF-E (hybrid); AY5USA-74905-PF-E (PBX) Features and Functions Max.
Number of Lines Supported 4,000 IP lines (per Media Gateway Controller [MGC]); 16,000 Internet Protocol (IP) lines maximum Max. Number of Ports Supported 16,000 IP ports maximum Max. Number of Simultaneous Calls Supported 12,096 Operating System (OS) NEC proprietary Busy Hour Call Completion (BHCC) Ratings 46,000 (1 MGC); 160,000 (up to 4 MGCs) Type of Switch Matrix Time Division Multiplexing (TDM) and IP Max. Number of Digital Phones Supported 870 (290 per Port Interface Rack [PIR]) Dterm Series E Phones Max. Number of Analog Phones Supported 870 (290 per PIR) Max. Number of IP Phones Supported 16,000 (NEC Dterm IP Phones) IP Standards Supported H.323 v.1 and v.2 (NEC Dterm IP Phones) Network Quality of Service (QOS) 802.1p/Q, Differentiated Services (DiffServ) and Type of Service (TOS) supported on NEAX IP trunks and IP line cards. Tecnotest Reflex Keygen Mac on this page.
Chapter 8 System Administration The method you use depends on how you installed and configured the device to which you want to connect. A serial cable direct connection offers better performance than a modem connection, but requires that the PC and device be within 50 feet of each other. A TCP/IP connection offers excellent performance and flexibility but requires a network connection to both your PC and the device. PBX Configuration Wizard The PBX Configuration Wizard is a custom tool in MAT WorX that enables you to establish the proper communication settings between your computer and the U NIVERGE NEAX 2000 IPS. The Wizard asks you simple questions and then uses the information to automatically configure the connection for the PC and the PBX.
Service Conditions 1. Connection through modems is available, providing remote maintenance capabilities. MAT WorX can be connected to the system either directly or remotely.
Direct connection is through the RS connector on the MP card. Remote connection is available via either an internal modem on the MP card or an external modem for high speed. Remote connection via the internal modem is through the COT card. Connection between the modem and the COT is accomplished through internal switching of the TDSW. Remote connection via an external modem is through the MP card. The following functions can be performed from MAT WorX: System, station, and trunk data entry, change, and copy. Loading, saving, and verification of system data to and from a disk.
ROM check readout of generic program. Display of fault/fault cleared messages.
On-siteor remote access to the system. Printout of system data (when printer is connected to PC). Display and setting of system clock/calendar.
Numbering Plan Least Cost Routing (LCR) System initialize UCD/Station Hunting/Call Pickup – Group 4. The PC used with MAT WorX must have an RS-232Cport, and cannot be located more than 50 feet (15m) from the system when connected on premises.
When stations or trunks are expanded, moved, or changed, office data for a Multiline Terminal key/station/ trunk can be copied and multiple assignments of related office data is possible. MACH Script Editor This is a powerful timesaving tool that enables you to create a list of U NIVERGE NEAX 2000 IPS commands that perform tasks in the PBX. This list is referred to as a script, which can be saved and run at anytime. You can also use the MACH Script Editor to perform many other operations. Traffic Management The U NIVERGE NEAX 2000 IPS provides traffic management reports to be used for overall analysis of system performance. MAT WorX is used to request and display the type of report, sample measurement time period, and time increments of reports.
Type of Traffic Measurement Reports: Number of successful attempts at outgoing access, based on trunk route. Number of times all trunks were busy, based on trunk route. Number of incoming calls, based on trunk route. Number of incoming calls connected to busy tone and then trunk abandoned. Quantity of incoming calls with no answer and trunk abandoned, based on trunk route. Number of times a push button register was connected, on a system basis.
Number of times all push button registers were busy, on a system basis. Number of outgoing connections using modem trunks, based on modem trunk group.
Number of incoming connections using modem trunks, based on modem trunk group. Number of times all modem trunks were busy, based on modem trunk group. Number of times the Conference circuits were used, on a system basis. Number of times Conference circuits were all busy, on a system basis. Number of times an incoming call was Call Forwarded-NoAnswer to the Attendant or another station (on DID, Tie or DIT lines), on a system basis. Number of Tandem Connections, on a system basis.
Number of times a push button register was connected to a trunk, based on trunk route. Number of Attendant calls including recalls, on a system basis. Number of station-to-stationcalls, on a system basis. Number of times senders were all busy, on a system basis. Number of ring generator capacity overflows, on a system basis. Number of DTE to DTE connections, on a system basis.
(UCD Peg Count) Number of answered calls by UCD group. Number of incoming calls by UCD group. Number of waiting calls for a pre-determinedtime into queuing mode on the UCD group. Number of incoming calls to all busy stations in the UCD group. Number of answered calls in the UCD group. MATWorX PC Requirements MAT WorX requires an IBM or compatible PC running Microsoft Windows ®ME, 2000 or XP.
Minimum Requirements Recommended Pentium III 350 MHz processor Pentium IV 1 GHz processor 128 MB RAM 256 MB RAM Available hard-diskspace Available hard-diskspace before installation: before installation: 200 MB - Full Installation 200 MB - Minimum installation MATWorX uses about 100 MB MATWorX uses about 100 MB SVGA monitor, 800 x 600 15” SVGA monitor, 1024 x resolution 768 resolution 3.5” diskette drive, CD-ROMdrive, Mouse Valid NEAX hardware connection (direct serial, modem, or TCP/IP). Chapter 8 System Administration System Diagnostics When a fault occurs in the system, an audible and visual indication will be given at the following units: External alarm indicating unit Fault messages reported at MAT WorX for remote reporting Alarm lamps in front of each package mounted in the frame Self Diagnostic/System Messages The U NIVERGE NEAX 2000 IPS provides a sophisticated array of self-diagnosticroutines that are continually and automatically being performed. Various system messages are printed when a fault occurs in a central processor system, switch network processors. Mossberg 402 Palomino Manual more. Many other miscellaneous system messages and change of key status messages are also printed. Remote Maintenance This feature allows station and trunk changes or reassignments to be performed without a site visit by service personnel, and can be used to retrieve fault codes prior to visiting a site.
One Remote Maintenance center can service an unlimited amount of systems, thus reducing the amount of personnel to maintain each site, travel costs and customer billing for each site. Service Conditions 1.
The following additional equipment is required for this feature: A modem at the maintenance center and one at each remote site. (When the internal modem of the Main Processor (MP) is used, no modem at each remote site is required) A cable for connection between the MP and the on-sitemodem. (When the internal modem of the MP is used, the above cable is not required) 2. The internal modem of the MP is compatible with the following specifications: Modem Specification ITU-TV.22 1200 bps ITU-TV.32 4800/9600 bps ITU-TV.22 bis 2400 bps ITU-TV.34 19.2 k/33.6 kbps Bell 212A 1200 bps 3. Any one of the following connections are also required for access to the modem: Required Connection A dedicated line Attendant controlled transfer Direct Inward System Access (DISA) Direct Inward Termination 4. The following operations can be executed from the Remote Maintenance location: Retrieval of fault data Retrieval of Peg Count information Deletion or addition of system data (line, trunk, etc.) using a preprogrammed security password Data assignment by device number (stations, trunks, and Attendant Console) Copying of station data from one station to other stations (when adding sequential stations in groups) Release / Reconnection of backup batteries Display of station line status. MP Program Download The U NIVERGE NEAX 2000 IPS provides Online MP Program Download via IP network using the CP24C and CP31C.
This feature allows an MP upgrade program to be downloaded to the U NIVERGE NEAX 2000 IPS MP card with the PBX on-lineand during the download process all features and functions are available. The MP Program Download feature is available to a stand alone system or a Remote system in a Remote PIM network. The IPS downloads the MP upgrade program from FTP server using MATWorX. MATWorX and the FTP server can be installed and running on the same PC. A single FTP server or multiple FTP servers can be used. Immediate or scheduled changeover to the upgrade program is available.
It is also possible to change back to the previous program that was in use before the changeover (changeback). MP Download Process Service Conditions General Service Conditions The MP program download can be executed to the PN-CP24-C/PN-CP31-C(MP card) when a PZ-M606-Ais mounted.
For the Retrofit system and Backup CPU system remote download of MP program is not available. The call processing is stopped while the system is initialized by the program changeover execution. Remote download of AP program is not available. While the PBX is off-line,you cannot execute the program downloading, or program changeover/ changeback/ program version matching (immediate). However, it is possible to read various information and set the schedule (date/time) for program changeover/ changeback/ program version matching even while the PBX is off-line. When the PN-32IPLAis mounted in the system, the MP program download (FTP) is not available.
When the PN-32IPLA-Aor PN-8IPLAis mounted, it is available in the system. Chapter 8 System Administration Program Download Service Conditions Do not reset the PBX and the MATWorX during MP program downloading. Do not pull out the LAN cable during MP program downloading. FTP (File Transfer Protocol) is used as the protocol for the remote download of MP program. Only the file specified in “File Name” of CHECKSUM.TXT can be downloaded to the PBX.
If you do not set the directory name to save the program files and CHECKSUM.TXT by MATWorX, they are saved to the FTP directory (default). If you do not set the password and user ID of the FTP server by MATWorX, login to the FTP server with anonymous. If required FTP server information is not set when executing the MP program download, “DATA NOT SET” is displayed. For the TCP port, the specified port is used for file transfer (control), and the port in front of it is used for the file transfer. For example, when the TCP port is set to 3000, Port No.
3000 is used for the file transfer (control), and Port No. 2999 is used for the file transfer (Port 21-Filetransfer (control), Port 20-Filetransfer: default).
If you read the issue number of the standby side (outdated side) and change the settings of FTP information during MP program downloading, “WAIT, BUSY NOW” is displayed. When using a single FTP server to update multiple sites in remote PIM network schedule the file transfer at least 7 minutes or more apart so that bandwidth and the number of connections to the FTP server are not exceeded. Program Changeover Service Conditions The system is initialized automatically after executing the program changeover any data that is not backed up will lost. Be sure to execute the office data backup before executing the program changeover. If an error is detected during system initialization after executing the program changeover, the PBX starts automatically with the previous program. If the program download is executed while the program version matching is being executed, the program version matching is interrupted, and program download is executed.
If the program changeover (immediate) is executed while the program version matching is being executed, the program is changed after the program version matching is completed. The program changeover cannot be executed if the program downloading or program version matching is interrupted or fails. If the program changeover (immediate) is set, the setting is invalid.
The program changeover for which the schedule (date/time) has been set is executed only when the PBX is on-line. When immediate program changeover is executed after a schedule (date/time) for program changeover execution is set, the schedule is invalid. Required Hardware Equipment Comments CP24C/CP31C Stand Alone or Remote PIM network MATWorX IPS Version 11.0.0 PC for MATWorX Note See MATWorX PC Requirements above Windows 2000 Server/Windows 2000 PC/Work station for FTP Note Professional/Windows XP Professional (Internet Information Server (IIS)supplied with Windows 2000/XPProfessional can be used) Note: MATWorX and FTP server program can be used on the same PC. MA4000 Management System MA4000 Management System is a web based, powerful voice server management configuration suite.
MA4000 offers centralized management for the U NIVERGE NEAX 2000 IPS Voice Server as well as simple and powerful tools for managing moves, adds and changes. MA4000 also offers flexibility and security and allows the end user to manage their voice server in the same ways they manage their networks.